Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the insert-headers-and-footers domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/bstsecurity.com.br/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the essential-addons-for-elementor-lite domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/bstsecurity.com.br/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/bstsecurity.com.br/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wpforms-lite domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/bstsecurity.com.br/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wordpress-seo domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/bstsecurity.com.br/wp-includes/functions.php on line 6114
BST Security | PC1864PCBPOR - PAINEL DE CONTROLE - DSC |

PC1864PCBPOR – PAINEL DE CONTROLE – DSC

Em sua maioria a Central de Alarme é composta pela Central propriamente dita que é como se fosse sua base, também são necessários os sensores que são os responsáveis pela identificação de uma possível invasão, a sirene que fará o trabalho de alerta sonoro no caso de uma invasão. Os controles servem de ativação e desativação da central de alarme e por último tem a discadora que tem como objetivo fazer o disparo da informação através de um alarme para os telefones que estiverem cadastrados, como por exemplo, o seu ou de mais alguém da família.  Não podemos nos esquecer da alimentação da Central de Alarme que é feita através de uma bateria selada.

Description

  • 8 zonas a bordo
  • Expansível para 64 zonas com fio
  • Expansível para 64 zonas sem fio
  • 4 saídas PGM: expansíveis até 14 (PC5204, PC5208)
  • Programação de modelos
  • Conecte até 8 teclados supervisionados
  • 8 partições
  • buffer de 500 eventos
  • 95 códigos de usuário
  • Compatível com CP-01
  • Suporta teclados sem fio com transceptor TR5164-433
  • Compatível com serviços interativos de ponta suportados pelo DSC
  • O painel PowerSeries suporta  termostato de hub inteligente LUX KONOzw  (requer comunicador Alarm.com).